🔥 Join the Fire Safety Movement! 🔥             Help us Spread Awareness about Passive Fire Protection and Prevent Fire Accidents!            Partner With Us to Educate Communities and Businesses About the Vital Role of Passive Fire Safety.           "Discover Insights, Latest Developments, and Best Practices in Passive Fire Safety."           “PASSiVE FIRE SAFE INDIA” Purely Dedicated on Passive Fire Safety.            An Unique Platform for B2b and B2c Magazine for the Passive Fire System.
Time :
Expert Talk / Published in May - June 2024 Edition

Quality Mechanical Ventilation Systems = Quality Air for All

-by Arindham Bhadra

Breathing comes so naturally to us that we are sometimes barely conscious of it. But, bad air quality can affect us in many ways—from mere discomfort to loss of life. Since a lot of us spend time indoors nowadays, how do we ensure that the air we breathe is safe?

This is where the Mechanical Ventilation System comes in; it plays a major part in our daily lives by

  • circulating the air in buildings so that all occupants are able to enjoy good air quality

  • continuously replacing the air from the space with fresh, outdoor air

  • removing heat from the space and also possible contaminants, such as products of respiration, bacteria, odours, products of combustion, building materials and furnishings, etc.

The role of the Mechanical Ventilation System in Fire Protection

The Mechanical Ventilation System is also a key component of fire safety. In the event of a fire, smoke and polluted air can spread rapidly throughout the building and in most incidents, death and injuries usually result from smoke inhalation rather than the heat from the flames.

This system reduces the risk factors by ensuring that the evacuation routes are safe and secure for people to leave the building.

Who is responsible for the Mechanical Ventilation System?

Thus, according to the requirements from 1) the Code of Practice for Fire Precautions in Building 2018 (Fire Code 2018) - Chapter 7 and 2) the Code of Practice for air-conditioning and mechanical ventilation in building (SS 553: 2016+A1: 2017), Building Owners and Council Members are responsible for installing the Mechanical Ventilation System to

  • Provide air ventilation in the building where natural ventilation is not a suitable or effective smoke control measure

  • To purge or prevent smoke build-up in certain key aspects of the building, especially where means of escape are critical in the event of fire i.e. staircases

Additional Requirements:

  • The common frequency of inspection, testing and maintenance of the Mechanical Ventilation System in buildings, as per regulations, is monthly

  • In any building of which habitable height exceeds 24m, any internal exit staircases without provision for natural ventilation shall be pressurized to comply with the requirements

  • In a building comprising more than 4 basement storeys, any exit staircase connected to fire fighting lobby in basement storeys shall be pressurized to comply with the requirements

Basic features of the Mechanical Ventilation System

The system is made up primarily of 4 types of mechanical ventilation system that you will usually hear or see in use:

Jet Fan (High and Low speed)

  • Also known as impulse or induction fans

  • Usually used at underground carparks and multi-storey carparks where due to exhaust gases, the air is severely contaminated with carbon monoxide, nitrogen oxide and LPG. The Jet Fan is use to quickly extract the polluted air from the area.

  • Supports the natural flow between the supply air and extract air zones, without ducts

Fresh Air Fan

  • Supports the inflow of fresh air from the external environment into the building

Exhaust Fan

  • Supports the extraction of polluted air or smoke out of the area and/ or building, usually installed with ducts

Pressurization Fan

  • Supports the pressurization of staircases that does not allow for natural ventilation of purging smoke out of the stairway that is the emergency escape route for the building

Where is the Mechanical Ventilation System found?

  • Car parks

  • Kitchens

  • Bathrooms, toilets and locker rooms

  • Exit facilities

  • Fire Command Centre

  • Engine driven pump room

  • Generator room

  • Spaces involving the use of flammable and explosive substances

How BSE Can Help?

Fire Protection Specialists like BSE, MCST Managing agencies, and/ or technicians are engaged to assist Building Owners and Council Members. We provide the

  • Inspection of the Mechanical Ventilation System and equipment

  • Testing of Mechanical Ventilation System and equipment under fire and fault conditions

  • Identification of defects for recommendation and rectification in a timely manner Ventilation is important, and many factors can influence how well it works or if the building has the proper balance of air flow throughout especially in the event of a fire incident. Contact us today to find out how we can value-add to your existing Fire Protection Maintenance Services.

Tips On an Optimum Mechanical Ventilation System

  • Ensure that TESTS are conducted based on Pressurization Systems (Code of Practice for Fire Precautions in Buildings)

  • Ensure that SIGNALS from the Fire Alarm Panel can AUTOMATICALLY ACTIVATE the Fan Controller Panel to trigger the system in the event of fire

  • Ensure there are NO OBSTRUCTIONS or blockages at the start and end of the duct-work or fan grille to ensure that the proper airflow path is being observed

The 4th Edition of Fire Directory

Passive Fire Magazine

Newsletter

Aliqu justo et labore at eirmod justo sea erat diam dolor diam vero kasd

Sit eirmod nonumy kasd eirmod

About Us

With a very different concept, the magazine received tremendous and positive response. Passive Fire Safe India is the first magazine covering the Passive Fire segment. Passive fire protection involves Read More..

© Passive Fire Safe India. 2024-25 All Rights Reserved. Designed by VMH Web Solutions