Quality Mechanical Ventilation Systems = Quality Air for All
-by Arindham Bhadra
Breathing comes so naturally to us that we are sometimes barely conscious of it. But, bad air quality can affect us in many ways—from mere discomfort to loss of life. Since a lot of us spend time indoors nowadays, how do we ensure that the air we breathe is safe?
This is where the Mechanical Ventilation System comes in; it plays a major part in our daily lives by
circulating the air in buildings so that all occupants are able to enjoy good air quality
continuously replacing the air from the space with fresh, outdoor air
removing heat from the space and also possible contaminants, such as products of respiration, bacteria, odours, products of combustion, building materials and furnishings, etc.
The role of the Mechanical Ventilation System in Fire Protection
The Mechanical Ventilation System is also a key component of fire safety. In the event of a fire, smoke and polluted air can spread rapidly throughout the building and in most incidents, death and injuries usually result from smoke inhalation rather than the heat from the flames.
This system reduces the risk factors by ensuring that the evacuation routes are safe and secure for people to leave the building.
Who is responsible for the Mechanical Ventilation System?
Thus, according to the requirements from 1) the Code of Practice for Fire Precautions in Building 2018 (Fire Code 2018) - Chapter 7 and 2) the Code of Practice for air-conditioning and mechanical ventilation in building (SS 553: 2016+A1: 2017), Building Owners and Council Members are responsible for installing the Mechanical Ventilation System to
Provide air ventilation in the building where natural ventilation is not a suitable or effective smoke control measure
To purge or prevent smoke build-up in certain key aspects of the building, especially where means of escape are critical in the event of fire i.e. staircases
Additional Requirements:
The common frequency of inspection, testing and maintenance of the Mechanical Ventilation System in buildings, as per regulations, is monthly
In any building of which habitable height exceeds 24m, any internal exit staircases without provision for natural ventilation shall be pressurized to comply with the requirements
In a building comprising more than 4 basement storeys, any exit staircase connected to fire fighting lobby in basement storeys shall be pressurized to comply with the requirements
Basic features of the Mechanical Ventilation System
The system is made up primarily of 4 types of mechanical ventilation system that you will usually hear or see in use:
Jet Fan (High and Low speed)
Also known as impulse or induction fans
Usually used at underground carparks and multi-storey carparks where due to exhaust gases, the air is severely contaminated with carbon monoxide, nitrogen oxide and LPG. The Jet Fan is use to quickly extract the polluted air from the area.
Supports the natural flow between the supply air and extract air zones, without ducts
Fresh Air Fan
Exhaust Fan
Pressurization Fan
Where is the Mechanical Ventilation System found?
How BSE Can Help?
Fire Protection Specialists like BSE, MCST Managing agencies, and/ or technicians are engaged to assist Building Owners and Council Members. We provide the
Inspection of the Mechanical Ventilation System and equipment
Testing of Mechanical Ventilation System and equipment under fire and fault conditions
Identification of defects for recommendation and rectification in a timely manner
Ventilation is important, and many factors can influence how well it works or if the building has the proper balance of air flow throughout especially in the event of a fire incident. Contact us today to find out how we can value-add to your existing Fire Protection Maintenance Services.
Tips On an Optimum Mechanical Ventilation System
Ensure that TESTS are conducted based on Pressurization Systems (Code of Practice for Fire Precautions in Buildings)
Ensure that SIGNALS from the Fire Alarm Panel can AUTOMATICALLY ACTIVATE the Fan Controller Panel to trigger the system in the event of fire
Ensure there are NO OBSTRUCTIONS or blockages at the start and end of the duct-work or fan grille to ensure that the proper airflow path is being observed