Trending
🔥 Join the Fire Safety Movement! 🔥             Help us Spread Awareness about Passive Fire Protection and Prevent Fire Accidents!            Partner With Us to Educate Communities and Businesses About the Vital Role of Passive Fire Safety.           "Discover Insights, Latest Developments, and Best Practices in Passive Fire Safety."           “PASSiVE FIRE SAFE INDIA” Purely Dedicated on Passive Fire Safety.            An Unique Platform for B2b and B2c Magazine for the Passive Fire System.
Time :
Recent- News / Published in May - June 2023 Edition

Gas, Vapour and Liquid Explosion Properties Testing

The handling of gases, liquids and selected substances may constitute risks for explosions. Knowing the properties related to the risk of these materials, such as the ignition and explosion characteristics, is therefore essential. By being aware of the properties of materials handled in your plant or used in your products, it allows the necessary safety precautions to be taken to prevent explosions or reduce their consequences.

Determination of the auto-ignition temperature of gases and vapours

The auto-ignition temperature of a substance is used to assess the ignition hazards of gases and vapours. The test is performed in a heated vessel into which the test sample is introduced. The temperature and sample concentration is varied until the threshold of ignition is determined. The test is performed according to EN 14522: ‘Determination of the auto-ignition temperature of gases and vapours.

Conductivity of liquids

This test measures the conductivity of liquids, which allows the evaluation of their electrostatic charging properties.

The conductivity of a liquid is an important measure to determine electrostatic ignition hazards. Low-conductivity liquids obtain charges. For example, during pouring or stirring operations—liquids with conductivities < 5×10-11 S m-1 are low enough that electrostatic hazards must be carefully guarded. However, for liquids with extremely low conductivity, i.e. conductivities < 10-13 S m-1, charge buildup occurs to a lesser extent and is not considered hazardous. These low-conductive liquids may be subject to incendive brush discharges. Liquids with high conductivity may be involved in static electrification accidents if they are placed inside insulated vessels or in the form of an aerosol.

Explosion limits

The bomb method as described in EN 1839: a quiescent mixture in a closed vessel (bomb) is subjected to an ignition source. The overpressure is measured. The amount of test substances in the mixture is varied until no significant overpressure is seen, thus determining the lower and upper explosion limits.

Maximum explosion overpressure and maximum rate of pressure rise

The maximum explosion overpressure and rate of pressure rise in a closed test vessel (bomb) as described in EN 15967. Explosive mixtures of the substance and air are prepared in the vessel at atmospheric conditions and ignited in the centre. The pressure-time history is measured. From the pressure-time histories the highest rate of pressure rise (dt/dt)m is calculated, and the highest pressure determined. This is performed over a large range of substance-air concentrations until the maximum values of both parameters have been obtained.

Laminar burning velocity

The bomb (closed vessel) method to determine the laminar burning velocity. Mixtures of the substance to be investigated and the air are prepared in the closed vessel using the partial pressure method. Ignition in the center yields a pressure-time history. Burning velocities are extracted from the pressure-time history. This is repeated over a large range of substance-air concentrations until the maximum value of the burning velocity is obtained.

The 4th Edition of Fire Directory

Passive Fire Magazine

Newsletter

Aliqu justo et labore at eirmod justo sea erat diam dolor diam vero kasd

Sit eirmod nonumy kasd eirmod

About Us

With a very different concept, the magazine received tremendous and positive response. Passive Fire Safe India is the first magazine covering the Passive Fire segment. Passive fire protection involves Read More..

© Passive Fire Safe India. 2024-25 All Rights Reserved. Designed by VMH Web Solutions